Syringe Pump Module Syringe Pump Series User’s Guide. Syringe Pump Module, including both hardware operations and software operations accessed through a PC. This section discusses important. Conventions used in this guide. Illustrations Unless otherwise indicated, the values in the illustrations of this manual are examples only. Norgren V6 Syringe Drive Pump. User guide. Download PDF for free and without registration! Norgren manuals. V6 Syringe Drive Pump. Download Norgren V6 Syringe Drive Pump User Manual – Download. Norgren V6 Syringe Drive Pump User Manual. Norgren / Hardware. Hardware User Manual 101 101101 CadentConnect Software (GUI) 102 101102. 2017 Norgren Kloehn, Inc. Cadent 3 Syringe Pump Warning Improper selection, misuse, age or malfunction of components used in systems can cause failure in various modes. The system designer/end user is responsible for verifying that all. Cv’s of 0.34 (1/8') and 0.98 (1/4') provide exceptionally high flow for the compact size of the valve, making the Super X ideal for a wide range of applications. All Super X Valves are warranted to be free from defects for a full two years from the date of purchase.
- Norgren Hardware User Manual 8 Syringe Pump Instructions
- Norgren Hardware User Manual 8 Syringe Pump System
- Instruction Manual
See Section ALE-24 for Accessories
ALE-16-12
Littleton, CO USA
Phone 303-794-2611
www.norgren.com
B38
● Compact instrument units with high performance
● Stable regulation with temperature compensation
● Excellent flow and regulation characteristics
● Panel Mounting facility
● Designed for use in corrosive environments
● Metallic parts meet NACE Standard MR-01-75*
● Applications include marine environments, oil and
gas production, chemical and food processing,
medical analysis
● Relieving or non relieving models. Relieving models
allow reduction of outlet pressure even when the
system is dead-ended
* National Association of Corrosion Engineers (NACE) MR-01-75 defines requirements for
sulphide stress cracking resistant materials used in well-head and other corrosive environments.
Filter/Regulator Stainless Steel Model
1/4 or 1/2” PTF
ISO Symbols
Automatic Drain, Relieving
Automatic Drain, Non Relieving
Manual Drain, Relieving
Manual Drain, Non Relieving
Outlet pressure range
Port Size
Model Number
psig (bar)
Flow** scfm (dm
3
/s)
Weight kg (lbs)
1/4” PTF
B38-240-B1KA
4 to 100 (0.3 to 7)
15 (7)
3.11 (1.4)
1/2” PTF
B38-440-M1LA
4 to 125 (0.3 to 9)
106 (50)
4.75 (2.2)
Ordering Information.
Models listed are relieving type with manual drain, 5µm element, and PTF threads. A gauge is not included.
** Typical flow with 175 psig (12 bar) inlet pressure, 115 psig (8 bar) set pressure and 15 psig (1 bar) droop from set.
Alternative Models
Port Size
Substitute
1/4” PTF
2
1/2” PTF
4
Materials
Substitute
Stainless steel, nitrile elastomers
4
Stainless steel, Viton elastomers
5 †
Threads
Substitute
PTF
A
ISO Rc taper
B
ISO G parallel
D
API.LP.INT
K
Outlet Pressure Adjustment Ranges* Substitute
0.6 to 30 psig (0.04 to 2 bar)
C
1 to 60 psig (0.07 to 4 bar)
F
3.6 to 100 psig (0.25 to 7 bar)
K †
4 to 125 psig (0.3 to 9 bar)
L ††
7.2 to 150 psig (0.5 to 10 bar)
M †
Element
Substitute
5 µm
1
25 µm
2
Bowl/Drain
Substitute
Long bowl with automatic drain
A
Short bowl with manual drain
B
Long bowl with manual drain
M
*
Outlet pressure can be adjusted to pressures in excess of, and less than, those specified.
Do not use these units to control pressures outside of the specified ranges.
†
1/4” ported units only.
†† 1/2” ported units only.
8
3
B
★ ★ ★ ★ ★ ★ ★
-
-
Diaphragm
Substitute
Relieving
0
Non relieving
1
Relieving, bracket and nut
2
Non relieving, bracket and nut
3
Relieving with nut
4
Non relieving with nut
5
Relieving with handwheel and nut
6
Norgren Hardware User Manual 8 Syringe Pump Instructions
Non relieving with handwheel and nut
7
Relieving with handwheel, bracket and nut
8
Non relieving with handwheel, bracket and nut
9
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
© Norgren Kloehn, Inc. 2012
4/13
PDS-0005 REV 7
V6 Syringe Drive Pump
Physical
Height
10'
Width
2.55'
Depth
4.75' (face plate to back plate)
4.9' to card edge
Weight
5.14 lbs.
Environmental
Operating Temperature
32°F to 131°F (0°C to 55°C)
Operating Humidity
5 to 95% RH, non-condensing at
131°F (55°C)
Storage Temperature
13°F to 185°F (–25° to 85°C)
WEEE & RoHS compliant
Mechanical
Operation
Any orientation
Mounting Holes
Top and bottom as well as on
the face plate
Resolutions Available
(12000; 24000; and
48000 increments)
Speed
(Max. – 10000 steps/sec.;
min. 60 steps / sec.)
(Default – 5000 steps/sec.)
Syringe Size
25ul to 50ml
Valve Type
2 way to 12 way
Available with no valve; solenoid
valve; or rotary valve
PC board choices:
Base board (sensor array and
motor pin out only - no motor
drivers or control electronics).
Driver board (sensor array and
motor drivers only, no control
electronics).
Driver & Control boards (fully
functional motor drivers and
control electronics).
Card-edge connector
Integrated RS232
Integrated power filter
Norgren Hardware User Manual 8 Syringe Pump System
Multiple valve choices
Including no valve & solenoid valve
Interface
RS-485 or RS-232 communications
Data terminal or OEM protocol
1200 to 38.4K baud, 8 data bits,
1 stop bit, no parity, half duplex
Three inputs, three output ports
Digital voltmeter
Switched and wired device address
Power
Instruction Manual
Operation
24V (with a maximum power voltage
ripple of 720mv peak-to-peak).
Power Consumption
40 watts, 11 watts idle.
The VersaPump 6 is a programmable precision liquid
metering instrument with non-volatile user program
memory and system input/output (I/O). The V6 is
designed with the flexibility and versatility to meet
a variety of system configurations. It can be used as
a stand alone controller, or integrated into system
configurations. The module is capable of simple closed
loop control of an external quantity or process without
the need of an external controller for direction.
Mechanically, the syringe pump is driven via stepper
motor and precision ball screw. It has a 60mm stroke
and is available in three resolutions. The pump can be
coupled with a variety of valves and syringes, as well
as PC board selections, to meet specific needs.
Pump communications are compatible with other
Kloehn devices.
1/10 Stroke Dispenses Full Stroke Dispenses
Precision: 0.10% CV, 0.20% max. 0.007% CV, 0.0092% max.
Accuracy: 0.20% CV, 0.60% max. ——